GE 16 SLICE BRIGHTSPEED CT SCANNER (Refurbished) Rotational: 0.5, 0.6, 0.7, 0.8, 0.9, 1, 2, 3, 4, seconds16 x 0.625mm routine thin slice scanningHiLight/Lumex Detector Technology. 16 x 0.625mm routine thin slice scanningPerformix 6.3 MHu X-Ray TubeFocal spots: 0.6 x 0.7 and 0.9 x 0.9. High Frequency JEDI generator Software Options:Direct 3DAuto MADirect MPRData ExportConnectProHelical Tilt Smart SpeedCopyComposerPatient-16-SliceSmart PrepPower 440 GE 64 SLICE DISCOVERY HD 750 CT SCANNER 64-SliceWith ASiR Dose ReductionTechnologyPerseus X-Ray TubeDual Energy Gemstone Detector Software Options:3000 Image SeriesAuto Filter and TransferConnect ProCopy Composer,Data ExportExam SplitHigh ResolutionNeuro Filter, Patient 64 sliceSmart Prep, VCT Hi PowerSmart Score ProEKG ViewerAutoBone, Noise Reduction FilterAxial Shuttle Smart StepCardIQ Helical Shuttle.Enhanced GSI PHILLIPS BRILLIANCE CT SCANNER 64 (Refurbishing) Aperture Size: 70cm.Anode Heat Capacity 8 MHU.Oil-to-air cooling.100s maximum continuous scan time.Scan fields of view: 25, 50cm.Reconstruction fields of view: 5-50cm.Adaptive filtration for noise reduction: Built-in.64Minimum slice thickness: 0.6mm. C-ARM SIEMENS SIREMOBIL COMPACT With Digital SubstractionFlat Panel MonitorsOrbital movement 130° (-40° to + 90°)Converter control frequency 15 kHz to 30 kHzKV range 40 kV to 110 kV ANGIOGRAPHY SYSTEM- SIEMENS AVANTIC 13″ Image Intensifier (biggest in the market)23 Kw Generator (biggest in the market)Digital SubstractionRoad Mapping Applications:AngiographyCardiologyOrthopaedicsPain managementSurgery and moreNew Flat Panel monitors AMX4 PLUS GE Portable X-Ray with new batteries, calibrated and in excellent condition.Two 70 kVp, 10 mAs X−ray exposures0.75 mm focal spot (NEMA): 3-inch rotating anode: GE X-Ray tube model HRT09.Up to 50 high-quality exposures with a single charge. GE OEC 9900 60kHz high frequency.15kW full-wave.Up to 120kVp.Up to 75mA for radiographic film exposure.Continuous high level fluoro (HLF) up to 20mA.Digital spot up to 75mA. FUJIFILM CR PRIMA T-2 Processing Capacity: Up to 73 IPs/hr.Time to Start on Display:Min. 33 sec.Reading Specification: 10 pixels / mm, 5 pixels / mmSingle phase 50 – 60 Hz MINXRAY HF120 Monobloc HF generatorfull bridge invertermAs: 0.6 – 212 mAsFrequency: 80 kHzFuse Rating: 30 A AMERICOMP RAD ROOM Summit Collimator LX125 on Floor Mounted Summit Tube StandSingle Phase Generator: input 240 mA max. output 300mA4-Way Float Top TableWall Bucky DIGITAL GE MAMMO SENOGRAPHE ESSENTIAL 2D Large Digital Detector – 24 X 30 Cm (Amorphous Silicon)Tube- Apollo- Rotating Anode-Focal Spots: 0.1 and 0.3.KV: 22 – 49 mA: 4- 500 mAs. Single Phase.Motorized Controlled Compression. Programmable Speed. SID: 66 cmWorkstation: Hard Disk: 25.000 images capacity. DICOM: Storage, Query, Send, PrintMonitor 19” B & W lcd 1mp. Monitor Color LCD 3Mp EizoSet-Plexiglas. Plates (ds). Essential Diagnostic package. ACR breast phantomGantry-Console. 24 x 30 compression paddle. 19 x 23 magnification paddleSquare Compression Paddle. Small Round compression PaddleClear Frameless Compression Paddle. Mag Stand. Radiation Shield (Mavig)Manuals, Detector Plate. (2) Foot Pedals. Test phantom. Calibration Phantom MEDRAD STELLANT INJECTOR Flow Rate: 0.1 to 10 mL/sec in 0.1 mL incrementsVolume: 1 mL to syringe capacity in 1 mL incrementsProgrammable Pressure: 200 mL syringe: 325 psi, 2241 kPa100-240 VAC, 50/60 Hz, 300 Volts-AMPsSimultaneous injection of Contrast and Saline